diff options
author | Nathan Bossart <nathan@postgresql.org> | 2025-01-06 15:01:22 -0600 |
---|---|---|
committer | Nathan Bossart <nathan@postgresql.org> | 2025-01-06 15:01:22 -0600 |
commit | c758119e5bfb47b38cf957f9a5a37ceae96fa9b3 (patch) | |
tree | d94191ad4e777efe0d95f419245b2b55450d3ac0 /src/backend/utils/misc/guc_tables.c | |
parent | 5e68f6119268d8c76b860bb56014335697c687db (diff) | |
download | postgresql-c758119e5bfb47b38cf957f9a5a37ceae96fa9b3.tar.gz postgresql-c758119e5bfb47b38cf957f9a5a37ceae96fa9b3.zip |
Allow changing autovacuum_max_workers without restarting.
This commit introduces a new parameter named
autovacuum_worker_slots that controls how many autovacuum worker
slots to reserve during server startup. Modifying this new
parameter's value does require a server restart, but it should
typically be set to the upper bound of what you might realistically
need to set autovacuum_max_workers. With that new parameter in
place, autovacuum_max_workers can now be changed with a SIGHUP
(e.g., pg_ctl reload).
If autovacuum_max_workers is set higher than
autovacuum_worker_slots, a WARNING is emitted, and the server will
only start up to autovacuum_worker_slots workers at a given time.
If autovacuum_max_workers is set to a value less than the number of
currently-running autovacuum workers, the existing workers will
continue running, but no new workers will be started until the
number of running autovacuum workers drops below
autovacuum_max_workers.
Reviewed-by: Sami Imseih, Justin Pryzby, Robert Haas, Andres Freund, Yogesh Sharma
Discussion: https://postgr.es/m/20240410212344.GA1824549%40nathanxps13
Diffstat (limited to 'src/backend/utils/misc/guc_tables.c')
-rw-r--r-- | src/backend/utils/misc/guc_tables.c | 11 |
1 files changed, 10 insertions, 1 deletions
diff --git a/src/backend/utils/misc/guc_tables.c b/src/backend/utils/misc/guc_tables.c index 22f16a3b462..c9d8cd796a8 100644 --- a/src/backend/utils/misc/guc_tables.c +++ b/src/backend/utils/misc/guc_tables.c @@ -3467,7 +3467,16 @@ struct config_int ConfigureNamesInt[] = }, { /* see max_connections */ - {"autovacuum_max_workers", PGC_POSTMASTER, AUTOVACUUM, + {"autovacuum_worker_slots", PGC_POSTMASTER, AUTOVACUUM, + gettext_noop("Sets the number of backend slots to allocate for autovacuum workers."), + NULL + }, + &autovacuum_worker_slots, + 16, 1, MAX_BACKENDS, + NULL, NULL, NULL + }, + { + {"autovacuum_max_workers", PGC_SIGHUP, AUTOVACUUM, gettext_noop("Sets the maximum number of simultaneously running autovacuum worker processes."), NULL }, |